| Rated Capacity | 
100kg, 200kg, 250kg, 500kg, 1t, 2t, 5t, 10t, 20t, 30t | 
| Full Scale Output | 
2mV/V ± 1% | 
| Zero Balance | 
± 0.04mV/V | 
| Non-linearity | 
Cap. 2t: <±0.2%; Cap.≥5t: <±0.05% | 
| Repeatability | 
Cap. 2t: <±0.03%; Cap.≥5t: <±0.03% | 
| Hysteresis Error | 
Cap. 2t: <±0.1%; Cap.≥5t: <±0.05% | 
| Creep in 30 minutes | 
Cap. 2t: <±0.1%; Cap.≥5t: <±0.05% | 
| Input Resistance | 
Cap. 2t: 400Ω±20; Cap.≥5t: 770Ω±30 | 
| Output Resistance | 
Cap. 2t: 350Ω±3; Cap.≥5t: 700Ω±5 | 
| Recommended Excitation | 
10V (15V Maximum) | 
| Insulation Resistance | 
>2[50V DC] Ω | 
| Compensated Temperature Range | 
-10oC to 50oC / 14oF to 122oF | 
| Safe Overload | 
150% of full scale | 
| Breaking Overload | 
300% of full scale | 
| Seal Type | 
Welded Seal | 
| IP Rating | 
IP68 | 
 
 266AS, (100-5000)kg
 266AS, (10-20)t
Note: You may need a software that can open/view STEP files.