| Rated Capacity | 25kg, 50kg | 
| Full Scale Output | 2mV/V ± 1% | 
| Zero Balance | ± 0.04mV/V | 
| Non-linearity | < ± 0.2% | 
| Repeatability | < ± 0.03% | 
| Hysteresis Error | < ± 0.1% | 
| Creep in 30 minutes | < ± 0.1% | 
| Input Resistance | 400Ω ± 20Ω | 
| Output Resistance | 350Ω ± 3Ω | 
| Recommended Excitation | 10V (15V Maximum) | 
| Insulation Resistance | > 2GΩ (50V DC) | 
| Temperature Effect on Sensitivity | < ±0.0023% of Cn/k | 
| Temperature Effect on Zero Balance | < ± 0.0120% of Cn/k | 
| Nominal Temperature Range | -10°C to 40°C/14°F to 104°F | 
| Service Temperature Range | -30°C to 70°C/-20°F to 160°F | 
| Storage Temperature Range | -50°C to 85°C/-58°F to 185°F | 
| Safe Overload | 150% of full scale | 
| Breaking Overload | 300% of full scale | 
| Seal Type | Environmentally sealed | 
| IP Rating | IP66 | 
266AA Compression Load Cell
- Material: Aluminum
 - Rated Capacities: 25kg, 50kg
 - Full Scale Output: 2mV/V ± 1%
 - Safe Overload: 150%
 - Breaking Overload: 300%
 - IP Rating: IP66
 - CE and RoHS certified
 
Note: You may need a software that can open/view STEP files.