| Rated Capacities | 30kg, 50kg, 100kg, 150kg, 200kg, 300kg |
| Reference Max. Platform Size | 500mm x 500mm |
| Full Scale Output | 2mV/V ± 10% |
| Zero Balance | ± 0.02mV/V |
| Non-linearity | < ± 0.017% |
| Repeatability | < ± 0.017% |
| Hysteresis Error | < ± 0.017% |
| Creep in 30 minutes | < ± 0.023% |
| Input Resistance | 385Ω ± 15Ω |
| Output Resistance | 350Ω ± 3Ω |
| Recommended Excitation | 10V (15V Maximum) |
| Insulation Resistance | > 2GΩ (50V DC) |
| Temperature Effect on Sensitivity | < ±0.0012% of Cn/k |
| Temperature Effect on Zero Balance | < ± 0.0040% of Cn/k |
| Nominal Temperature Range | -10°C to 40°C/14°F to 104°F |
| Service Temperature Range | -18°C to 65°C/0°F to 149°F |
| Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
| Safe Overload | 150% of full scale |
| Breaking Overload | 300% of full scale |
| Seal Type | Environmentally sealed |
| IP Rating | IP66 |
108LSMT Single Point Load Cell
- Material: Stainless steel
- Rated Capacities: 30kg, 50kg, 100kg, 150kg, 200kg, 300kg
- Full Scale Output: 2mV/V ± 10%
- Safe Overload: 150%
- Breaking Overload: 300%
- IP Rating: IP66
- CE and RoHS certified
Note: You may need a software that can open/view STEP files.
| Manufacturer | Model |
| Mettler-Toledo | MT1241* |
| Mettler-Toledo | SSP1241 |
* Metter-Toledo MT1241 has an aluminum element